{"product_id":"roland-dryer-for-ra640","title":"Roland Dryer for RA640","description":"\u003csection style=\"font-family: Inter,Arial,Helvetica,sans-serif; line-height: 1.55; color: #1f2937;\"\u003e\n\u003cdiv style=\"max-width: 940px; margin: auto;\"\u003e\n\u003ch1 style=\"margin: 0 0 10px; font-size: 28px; font-weight: bold;\"\u003eRoland IR Heater \u0026amp; Blower Dryer (Print-Synchronous)\u003c\/h1\u003e\n\u003cp style=\"margin: 0 0 14px; font-size: 15px;\"\u003eCompatible with \u003cstrong\u003eRoland RA-640 \/ RE-640 \/ RF-640 \/ RF-640A \/ XF-640\u003c\/strong\u003e. A combined \u003cstrong\u003einfrared heater + blower\u003c\/strong\u003e system designed for modern high-speed printing, accelerating ink fixation and media drying while keeping output quality stable.\u003c\/p\u003e\n\u003c!-- Key badges --\u003e\n\u003cdiv style=\"display: flex; gap: 8px; flex-wrap: wrap; margin: 12px 0 18px;\"\u003e\n\u003cspan style=\"background: #eef2ff; color: #3730a3; border-radius: 999px; padding: 6px 10px; font-size: 12px;\"\u003ePrint-synchronous auto ON\/OFF\u003c\/span\u003e \u003cspan style=\"background: #ecfeff; color: #155e75; border-radius: 999px; padding: 6px 10px; font-size: 12px;\"\u003eIR heat + blower — use together or independently\u003c\/span\u003e \u003cspan style=\"background: #fef3c7; color: #92400e; border-radius: 999px; padding: 6px 10px; font-size: 12px;\"\u003e180–260V · \u0026lt; 2000W\u003c\/span\u003e \u003cspan style=\"background: #f1f5f9; color: #0f172a; border-radius: 999px; padding: 6px 10px; font-size: 12px;\"\u003eWidths: 1.6 m \/ 1.8 m\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- Highlights --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 10px 0 18px;\"\u003e\n\u003cdiv style=\"border: 1px solid #e5e7eb; border-radius: 12px; padding: 14px; background: #ffffff;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 16px;\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eTwo sizes available: \u003cstrong\u003e1.6 m\u003c\/strong\u003e and \u003cstrong\u003e1.8 m\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eMounting options: \u003cstrong\u003ehanging bracket\u003c\/strong\u003e or \u003cstrong\u003eangle-iron floor stand\u003c\/strong\u003e (select as needed).\u003c\/li\u003e\n\u003cli\u003eBlower module: approx. \u003cstrong\u003e80 × 80 × 25 mm\u003c\/strong\u003e footprint.\u003c\/li\u003e\n\u003cli\u003eIR tube length: \u003cstrong\u003e~1690 mm\u003c\/strong\u003e for 1.6 m model.\u003c\/li\u003e\n\u003cli\u003eHeater and blower can run \u003cstrong\u003eindependently\u003c\/strong\u003e or in \u003cstrong\u003ecombined\u003c\/strong\u003e mode.\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cstrong\u003eprint-synchronous\u003c\/strong\u003e function: turns on with printing and turns off after job completion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e5e7eb; border-radius: 12px; padding: 14px; background: #ffffff;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 16px;\"\u003eThermal \u0026amp; Airflow Design\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eHigh heat-transfer efficiency; reflective panel directs up to \u003cstrong\u003e~85%\u003c\/strong\u003e of IR energy toward the media.\u003c\/li\u003e\n\u003cli\u003eResidual heat is removed by a controlled airflow path to maintain system stability.\u003c\/li\u003e\n\u003cli\u003eOptimized air ducting provides \u003cstrong\u003eeven, uniform airflow\u003c\/strong\u003e across the print width.\u003c\/li\u003e\n\u003cli\u003eSurface temperature designed to remain close to ambient for operator safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Sync control --\u003e\n\u003cdiv style=\"border: 1px solid #e5e7eb; border-radius: 12px; padding: 14px; background: #f8fafc; margin-bottom: 18px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 16px;\"\u003ePrint-Synchronous Control (GX16 2-pin)\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 8px; font-size: 14px;\"\u003e\u003cstrong\u003eConnector:\u003c\/strong\u003e Aviation plug \u003cstrong\u003eGX16, 2-core\u003c\/strong\u003e. Wire-1: \u003cstrong\u003eRed\u003c\/strong\u003e (+), Wire-2: \u003cstrong\u003eBlack\u003c\/strong\u003e (–).\u003c\/p\u003e\n\u003cp style=\"margin: 0 8px 8px; font-size: 14px;\"\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e DC \u003cstrong\u003e5–24 V\u003c\/strong\u003e, \u003cstrong\u003e10–40 mA\u003c\/strong\u003e. (5 V recommended to reduce current.)\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 6px; font-size: 14px;\"\u003e\u003cstrong\u003eTypical signal sources\u003c\/strong\u003e from the printer:\u003c\/p\u003e\n\u003col style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003ePrint start\/stop synchronization output.\u003c\/li\u003e\n\u003cli\u003eMedia\/home (origin) sensor.\u003c\/li\u003e\n\u003cli\u003eTake-up or exhaust fan trigger.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"margin: 8px 0 0; font-size: 13px; color: #475569;\"\u003eExample (GP1A05 photo-sensor): connect \u003cem\u003ered\u003c\/em\u003e to \u003cstrong\u003eVcc\u003c\/strong\u003e, \u003cem\u003eblack\u003c\/em\u003e to \u003cstrong\u003eVo\u003c\/strong\u003e. Other sensors follow similar wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Specs --\u003e\n\u003ch3 style=\"margin: 6px 0 8px; font-size: 16px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb; background: #fcfcfd; width: 220px;\"\u003eModel Widths\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb;\"\u003e1.6 m \/ 1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb; background: #fcfcfd;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb;\"\u003eAC \u003cstrong\u003e180–260 V\u003c\/strong\u003e, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb; background: #fcfcfd;\"\u003eRated Power\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb;\"\u003e\n\u003cstrong\u003e\u0026lt; 2000 W\u003c\/strong\u003e (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb; background: #fcfcfd;\"\u003eControl\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb;\"\u003ePrint-synchronous auto on\/off; manual control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb; background: #fcfcfd;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #e5e7eb;\"\u003eHanging bracket or floor stand (angle-iron) — choose per installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- In the box --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(260px,1fr)); gap: 18px; margin: 18px 0;\"\u003e\n\u003cdiv style=\"border: 1px solid #e5e7eb; border-radius: 12px; padding: 14px; background: #ffffff;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 16px;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eIR heater assembly with integrated blower\u003c\/li\u003e\n\u003cli\u003eControl box \/ panel\u003c\/li\u003e\n\u003cli\u003ePower cable\u003c\/li\u003e\n\u003cli\u003eMounting kit (brackets or stand, depending on selection)\u003c\/li\u003e\n\u003cli\u003eUser wiring guide for print-sync (GX16)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e5e7eb; border-radius: 12px; padding: 14px; background: #ffffff;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; font-size: 16px;\"\u003eNotes\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eEnsure proper grounding and follow local electrical codes.\u003c\/li\u003e\n\u003cli\u003eKeep airflow unobstructed; do not cover the outlet or reflective surface.\u003c\/li\u003e\n\u003cli\u003eUse print-sync only with the specified voltage\/current range.\u003c\/li\u003e\n\u003cli\u003eAllow cooling before service; IR tubes are hot during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Compatibility --\u003e\n\u003cp style=\"margin: 6px 0 0; font-size: 13px; color: #475569;\"\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Roland RA-640, RE-640, RF-640, RF-640A, XF-640 (and systems with similar 1.6–1.8 m carriages).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"UV INK PRO","offers":[{"title":"Default Title","offer_id":44273959174230,"sku":null,"price":117.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0691\/3782\/5878\/files\/Roland-Dryer-for-RA640-1.webp?v=1775015168","url":"https:\/\/www.uvinkpro.com\/products\/roland-dryer-for-ra640","provider":"UV INK PRO","version":"1.0","type":"link"}